Carbon dioxide gas has several applications in commercial and industrial applications. As such, there needs to be a mechanisms for safe storage and use to avoid the potential hazards the gas can cause. To solve this problem, carbon-dioxide gas is stored in cylinders as a compressed liquefied gas and increasing its temperature results in an increase in pressure.

Sometimes the pressure can be too high to cause tanks to rupture. A rupturing cylinder can cause substantial injury and damage to property, and to avoid that, safety mechanisms are incorporated into the product. Bursting disks are fitted into the tanks so that when internal pressure exceeds 190 bar, they rupture. This releases all the gas without an explosion. A bang followed by a rushing sound may be heard when the discs rupture. When in search for a CO2 tank Chicago offers the best place to visit.

One will buy the gas when it is at a very low temperature, usually at -57 to -78 degrees Fahrenheit. At these temperatures, the pressure generated on the walls of a cylinder is only 100 PSI. However, raising the temperature to room temperature causes an increase in pressure to 850 PSI. Increasing the temperature further to 110 degrees increases the pressure to 2000 PSI.

At such pressures, the tank is likely to rupture. For additional safety, only 34 percent of the volume of the tank is refilled. When that percentage is exceeded, even at low temperatures, the gas would place too much pressure on the cylinder and rupture it. As such, the storage location must be maintained cool at all times.

All tanks are accompanied by safety instructions for users to read and follow. The most important instruction is to connect the cylinder to a reducing valve or a regulator at all times when in use. If this is not done, the cylinder may explode when the cylinder valve is opened. When in use, the cylinder must be kept in an upright position. One should always keep the product away from children.

Most regulators usually have one or two gauges incorporated into them. The regulators with one gauge are the ones needed in most applications. The arrow in the gauge usually points at the pressure level at which the cylinder is delivering the gas. The second gauge is usually meant for measuring the amount of gas left in the cylinder at any given time. Therefore, one can always know how much gas they are left with before they need a refill.

Tanks should be bought depending on how much room one has for storage. One can get a grasp of how much room they need by visiting a local brewery to see what happens there. The mistake most people make is to buy tanks that are either too small or too big for the storage space they have. The storage should also be cool with low level ventilation.

Closed, unventilated vehicles should never be used for the transportation of tanks and one should avoid handling them using wet hands. When there are several tanks in a place, one must label each one of them very well before storing them. Finally, to make sure everything is okay, regular inspections should be done.